Rusting, Sticking Sliding Gates in Mauritius: Hot-Dip Galvanising, Powder Coating and a Properly Founded Track
Why steel sliding gates in Mauritius rust from inside and start sticking on their rails, and how a hot-dip galvanised and powder-coated gate on a concrete-founded V-groove track avoids both problems.
Background
A sliding gate is often the first thing visitors see of a house, and one of the few pieces of steelwork exposed to the weather every day of its life. In Mauritius that means intense sun, high humidity, heavy summer rains, cyclone winds and, close to the coast, salt-laden air. Many gates that look smart on the day they are installed are rusting at the welds within a couple of years and dragging along their rail soon after.
This article explains the recommended solution we proposed for a residential client who needed a new manual sliding gate of about 4.6 m wide by 2.0 m high, and why the specification matters as much as the design.
The problem and symptoms
Owners replacing a sliding gate usually describe some combination of the following:
- Rust spots and orange streaks at welds, joints and the bottom rail, with paint bubbling or flaking.
- Hollow sections that rust through from the inside, sometimes only discovered when a bar breaks off.
- A gate that becomes heavy to push, catches at one point, or rides off its track.
- Rollers that grind or seize, and a ground rail that is bent, loose or has sunk in places.
- A gate that rattles in strong wind because the top guide is worn or poorly aligned.
Investigation and diagnosis
When assessing an existing gate or specifying a new one, the points to check are:
- Corrosion protection: was the steel galvanised, or simply primed and painted? Paint-only systems on bare steel fail first at welds and edges.
- Hollow sections: does the inside of the tubes have any protection at all?
- Track foundation: is the ground rail fixed to a continuous concrete strip, or laid on paving or soil that can settle?
- Running gear: roller size and bearing quality relative to the gate weight, and the condition of the top guide rollers.
- Posts: are the guide and receiver posts plumb, rigid and set in concrete footings?
Root cause
Corrosion: paint alone is not enough
Steel rusts when water and oxygen reach its surface; chlorides from sea air accelerate the reaction considerably. Paint is a barrier, but every barrier has weak points: sharp edges where the film is thin, welds that were not cleaned, scratches from use, and the inside of hollow sections that paint never reaches. Once moisture gets under the paint at one of these points, rust spreads beneath the film and lifts it. In a humid, salty climate this happens quickly.
Sticking: the rail is only as good as what it sits on
A sliding gate concentrates its whole weight on two rollers running on a narrow rail. If that rail sits on ground or paving that settles unevenly after rain, the track develops dips and humps. The gate then binds, the rollers wear on one side, and in the worst cases the gate leaves the rail. Under-sized rollers with poor bearings, and grit packed into the groove, make the problem worse.
Recommended solution
The recommended specification addresses both failure modes at the source.
1. A galvanised and powder-coated gate (duplex system)
- Frame and infill fabricated from square and rectangular hollow sections (SHS/RHS) with vertical bar infill.
- Hot-dip galvanising after fabrication: the finished gate is dipped in molten zinc, so the coating covers welds, edges and the inside of the hollow sections. Zinc also protects sacrificially: if the surface is scratched, the surrounding zinc corrodes in preference to the steel.
- Polyester powder coating over the galvanising, in the client's choice of colour. The powder coat provides the decorative finish and an extra barrier that slows the consumption of the zinc. Together, a duplex system typically lasts considerably longer than either coating alone, which is why it is good practice for coastal and humid environments.
2. A track on a concrete strip foundation
- Excavation and a concrete strip foundation along the length of travel, so the ground track is supported continuously and cannot settle in patches.
- A V-groove ground rail with two heavy-duty V-groove rollers, which self-centre the gate on the rail and resist sideways movement.
- A gate stopper to prevent the gate over-running its track.
3. Rigid guide and receiver posts
- A steel guide post with top guide rollers to hold the gate upright and stable in wind, and a receiver post for the closed position, both hot-dip galvanised and powder coated.
- Posts set in concrete footings so they stay plumb under repeated use and cyclone gusts.
4. Security and commissioning
- A heavy-duty sliding gate lock with keys.
- Installation, alignment and testing of the gate operation, and making good of the civil works on completion.
Expected outcome
A gate protected inside and out by zinc, with a powder-coat finish on top, is far better equipped to resist the corrosion that ruins painted gates in Mauritius. Running on a continuously supported V-groove track with properly sized rollers and rigid posts, it should remain light to slide by hand and stay aligned, rather than progressively binding as the ground moves. A gate that runs freely by hand is also exactly what a motor kit needs if the owner chooses to automate it later.
Lessons and prevention
- Specify hot-dip galvanising after fabrication, not galvanised tube welded and painted afterwards; welding burns off the zinc at the joints.
- Avoid cutting or modifying after galvanising; where unavoidable, treat the bare steel with a zinc-rich repair coating.
- Keep the groove clean. Sweep sand, gravel and leaves from the rail regularly; grit is the main cause of roller wear.
- Rinse coastal gates with fresh water periodically to remove salt deposits, and touch up any chips in the powder coat promptly.
- Check the rollers and top guides once or twice a year, particularly before the cyclone season, and replace worn parts before they damage the rail.