BUILDING & FACILITIESCONTRACTING LTD

Home / Technical articles / Leaking Bathroom Over a Neighbour’s Ceiling: Waterproofing …

Leaking Bathroom Over a Neighbour’s Ceiling: Waterproofing Failure and Drain Pipe Fall

Waterproofing & roofing8 November 2026 · 3 min read

Why apartment bathrooms leak into the unit below, how we diagnosed a failed waterproofing membrane and a poorly falling drain pipe, and the full reinstatement that fixes it for good.

Background

Bathrooms in apartment blocks are one of the most common sources of water damage in Mauritius. A wet room sits directly above a neighbour's ceiling, is washed daily and, in our humid climate, rarely dries out completely. When the waterproofing under the tiles fails, the first sign is usually not in the bathroom at all, but as staining, flaking paint or dripping on the ceiling of the unit below.

This article describes a typical case we were asked to assess: an apartment bathroom with recurring leaks and a poorly routed drain pipe on the outside of the building.

The problem and symptoms

  • Damp patches and paint blistering on the ceiling of the flat below, worsening after showers.
  • Hollow-sounding and cracked floor tiles, with blackened grout lines around the shower area and the floor drain.
  • A discharge pipe on the external wall laid with insufficient fall, so water ponded in the pipe and seeped at the joints.

Investigation and diagnosis

Tapping the tiles revealed large debonded areas, which means water had been travelling under the tiles for some time. Grout and silicone at the wall–floor junction had broken down, giving water a direct path into the screed. Once tiles were lifted at a test location, the original waterproofing layer was found to be brittle, cracked at the corners and discontinuous around the pipe penetrations — the three places where membranes most often fail.

Externally, the discharge pipe had joints that were not watertight and a section running almost flat, so it never drained fully. Standing water in a pipe means constant pressure on every joint.

Root cause

The failure was a combination of three things: an ageing waterproofing membrane that had lost its flexibility, no reinforcement at corners and penetrations where the building naturally moves, and a drain pipe without proper fall. Tiles and grout are not waterproof on their own; they only protect the membrane underneath. Once the membrane failed, every shower was effectively watering the slab.

Solution

Patching individual tiles would not have solved the problem, because the leak path was under the whole floor. The recommended solution was a full reinstatement:

  1. Strip back to the substrate — remove all floor and wall tiles and the failed membrane, and clean the base so the new system bonds properly.
  2. Prime and waterproof — apply a primer followed by two coats of a flexible cementitious waterproofing membrane on the floor and up the walls, so the bathroom forms a continuous watertight tray.
  3. Reinforce the weak points — embed reinforcing tape at every corner, wall–floor junction and pipe penetration, which is where movement cracks first appear.
  4. Re-route the drain pipe — cut out the defective section and install new PVC pipework with a correct, continuous fall to the existing drainage, then test it for leaks before closing up.
  5. Re-tile and seal — fix new tiles on a suitable adhesive, grout fully, and seal all junctions and fittings with sanitary-grade silicone.

Scaffolding was included for safe access to the external pipework, as working from ladders on a building façade is neither safe nor practical for this kind of repair.

Expected outcome

A continuous, reinforced membrane under new tiles stops water reaching the slab, and a correctly falling drain removes standing water from the pipework. The ceiling below can then dry out and be repainted without the stains returning.

Lessons and prevention

  • Treat ceiling stains below a bathroom as a waterproofing problem, not a painting problem.
  • Inspect grout and silicone yearly and renew them as soon as they crack or darken — they are the first line of defence.
  • Corners and pipe penetrations need reinforcing tape; a membrane without it will crack there first.
  • Every drain pipe needs a continuous fall. A pipe that holds water will eventually leak at its joints.
Facing a similar issue? Call or WhatsApp the BFC Ltd contact number 5724 5224 or e-mail info@bfcltd.mu and our technical team will advise you.

Technical findings published by Building and Facilities Contracting Ltd, a CIA-registered contractor in Mauritius. Structural matters are always referred to a registered professional engineer. Details are generalised and client information is not disclosed.

Related articles

← All technical articles · Guides and insights

WhatsApp us